uvex_transients.phase_space.analysis.compare.difference_map#
- uvex_transients.phase_space.analysis.compare.difference_map(baseline: Table, comparison: Table, *, floor: float | None = None, check_meta: bool = True) Table[source]#
Difference two recovery maps, in dex of the recovered yield.
At every point of the plane the difference is \(\Delta = \log_{10}(R_\mathrm{c} / R_\mathrm{b})\), with \(R = f\,w\) the recovered yield of the comparison and the baseline map: the success fraction times the weight \(w\) that the sampler of the maps declares (
yield_weight, the volume-time \(\mathcal V T\) for a survey sampler, so that \(R\) is the recovered volume-time; a sampler with none compares the fractions). It is positive where the comparison recovers more. The maps are fitted independently, so the uncertainties of the two combine in quadrature, each taken from the half-width of the 1 sigma interval of the map.A point of a map cannot tell a recovery fraction much below one recovery in its
n_maxevents from none at all, so a map resolves \(f\) only down to about \(1/n_\mathrm{max}\). That is a limit of the measurement, not of what matters: a rare event can still be recovered often, where the volume-time is large, which is why the floor is on \(f\) and the rest of the difference is not cut. Wherever a map has \(f\) below floor, its \(f\) is replaced by floor: if only one map is below it, \(\Delta\) is then a bound (limit), and if both are, it is undefined (NaN).- Parameters:
baseline (
astropy.table.Table) – The two maps, as made bygrid_table(), or read frommap.ecsv. They need the columnsf,f_loandf_hiand the column theirweightmetadata names (the same for both), and must be on the same grid of the same axes. A map that records no weight is weighted by itsvolume_timecolumn if it has one.comparison (
astropy.table.Table) – The two maps, as made bygrid_table(), or read frommap.ecsv. They need the columnsf,f_loandf_hiand the column theirweightmetadata names (the same for both), and must be on the same grid of the same axes. A map that records no weight is weighted by itsvolume_timecolumn if it has one.floor (
float, optional) – The recovery fraction below which a map is taken not to have recovered anything. If None (the default), the coarser of the resolutions of the two maps, \(1/n_\mathrm{max}\) from then_maxthat each records. A map that does not (those made before it was recorded) is taken to resolve 1e-4.check_meta (
bool, optional) – Whether to require that the two maps agree on the quantities ofCOMPARED_METAthat they both record. A luminosity in one band is not one in another, so a comparison across them is only meaningful when it is deliberate. The default is True. The depth, the schedule and the definition of a detection are not checked, as they are what maps are most often compared for, and a map does not record them.
- Returns:
One row per grid point, in the order of the maps, with their two coordinates and
delta_dex\(\Delta\), in dex.
sigma_dexIts 1 sigma uncertainty, in dex.
delta_dex_lo,delta_dex_hi\(\Delta \mp \sigma\).
significance\(\Delta / \sigma\).
limit0 where \(\Delta\) is a measurement, +1 where the baseline is below floor so that \(\Delta\) is a lower bound, and -1 where the comparison is, so that it is an upper bound.
Its
metaholds thespace, the band, the unit of the luminosity and the zero point of the absolute magnitude (from the baseline), floor, and the metadata of each map asbaseline_*andcomparison_*.- Return type:
- Raises:
ValueError – If a map lacks a column, the maps are not on the same grid, or (with check_meta) they measure different axes.